Skip to main content
dd
CIC nanoGUNE
  • en
  • es
  • eu

User account menu

  • Sartu

Main Menu ES

  • nanoGUNE
    • Hitz bitan
    • Antolakuntza eta finantzaketa
    • Pertsonak
    • Bat egin
    • Bizi
    • Prentsa-bulegoa
    • nanoPeople
  • Ikerketa
    • Ikerketa
    • Argitalpenak
    • Proiektuak
    • Kanpo-zerbitzuak
  • Transferentzia
    • Transferentzia
    • Enpresa berriak
    • PI Zorroa
    • Industry collaborative research positions
    • Strategic lines
    • Kanpo-zerbitzuak
    • Albisteak
  • Formakuntza
    • Master projects
    • Gradu amaierako proiektuak
    • Udako praktikaldiak
    • Doktoretza programa
  • Gizartea

User menu

  • Sartu
  1. Azala
  2. nanoGUNE reaches new depths in infrared nanospectroscopy

nanoGUNE reaches new depths in infrared nanospectroscopy

2020/07/20

Researchers from the Nanooptics Group at CIC nanoGUNE demonstrate that nanoscale infrared imaging – which is established as a surface-sensitive technique – can be employed for chemical nanoidentification of materials that are located up to 100 nm below the surface. The results further show that the infrared signatures of thin surface layers differ from that of subsurface layers of the same material, which can be exploited to distinguish the two cases. The findings, recently published in Nature Communications, push the technique one important step further to quantitative chemometrics at the nanoscale in three dimensions.

Optical spectroscopy with infrared light, such as Fourier transform infrared (FTIR) spectroscopy, allows for chemical identification of organic and inorganic materials. The smallest objects which can be distinguished with conventional FTIR microscopes have sizes on the micrometre-scale. Scientists at nanoGUNE, however, employed nano-FTIR to resolve objects, which can be as small as a few nanometres.

In nano-FTIR (which is based on near-field optical microscopy), infrared light is scattered at a sharp metallized tip of a scanning-probe microscope. The tip is scanned across the surface of a sample of interest and the spectra of scattered light are recorded using Fourier transform detection principles. Recording of the tip-scattered light yields the sample’s infrared spectral properties and thus the chemical composition of an area located directly below the tip apex. Because the tip is scanned across the sample surface, nano-FTIR is typically considered to be a surface-characterization technique.

Importantly though, the infrared light that is nano-focussed by the tip does not only probe a nanometric area below the tip, but in fact probes a nanometric volume below the tip. Now the researchers at nanoGUNE showed that spectral signatures of materials located below the sample surface can be detected and chemically identified up to a depth of 100 nm. Furthermore, the researchers showed that nano-FTIR signals from thin surface layers differ from that of subsurface layers of the same material, which can be exploited for determination of the materials distribution within the sample. Remarkably, surface layers and subsurface layers can be distinguished directly from experimental data without involving time-consuming modelling.

For further information:

Subsurface chemical nanoidentification by nano-FTIR spectroscopy

L. Mester, A. A. Govyadinov, S. Chen, M. Goikoetxea & R. Hillenbrand

Nature Communications 11 (2020)

Tags
Chemical nanoimaging
Infrared spectroscopy (FTIR)
Near-field microscopy
Nano-FTIR
Nanospectroscop
Nanoidentification
  • whatsapp
  • facebook
  • twitter
  • linkedin
  • print

Lotutako albisteak

  • 2025/05/06

    NanoGUNEren Dorre Kuantikoa —The Quantum Tower— eraikitzen hasi da

  • 2025/04/01

    Donostia, spintronikaren eta orbitronikaren hiriburu

  • 2025/02/14

    Review Article Highlights 25 Years of Modern Near-field Optical Nanoimaging

  • 2025/02/11

    Scientists synthesize 2D polyaniline crystal with unique metallic out-of-plane conductivity

  • 2025/02/07

    Emakumeak Zientzianek berdintasunaren aldeko ekintza txiki bakoitzaren ahalmena azpimarratzen du

  • CIC nanoGUNE
  • Tolosa Hiribidea, 76
  • E-20018 Donostia / San Sebastian
  • +34 943 574 000 · nano@nanogune.eu
  • Facebook Twitter Youtube Linkedin Instagram Subscribe to our Newsletter

Menú pie principal

  • nanoGUNE
  • Ikerketa
  • Transferentzia
  • Formakuntza
  • Gizartea
  • nanoPeople

Menú pie servicios

  • Kanpo-zerbitzuak
  • Argitalpenak
  • Mintegiak
  • Bat egin
  • Prentsa-bulegoa
  • Kontratatzailearen profila
  • Corporate Compliance

Menú pie grupos

  • Nanomagnetismoa
  • Nanooptika
  • Self AssemblyAutomihiztadura
  • Nanobiosistemak
  • Nanogailuak
  • Mikroskopia Elektronikoa

Menú pie grupos 2

  • Teoria
  • Nanomaterialak
  • Detekzio Kuantikoko Mikroskopia
  • Nanoingeniaritza
  • Hardware Kuantikoa

Funded by

  • EJ/GV
  • Diputación
  • FEDER
  • FEDER
  • Ministerio de Ciencia e Innovación

Member of

  • BRTA
  • SOMM

Distinctions

  • Distinción de Excelencia María de Maeztu 2022-2025
  • Excellence Research
  • UNE-166002

Menú legales

  • Irisgarritasuna
  • Lege-oharra
  • Pribatutasun politika
  • Cookiei buruzko politika
  • Konfidentzialitate politika
by ACC